{"title":"Research","description":"\u003cp\u003eResearch grade products designed for quantitative imaging in life science, chemistry, physics, and high-precision industrial applications.\u003c\/p\u003e","products":[{"product_id":"triggerscope-4","title":"Triggerscope 4 - TTL\/DAC Controller","description":"\u003cp class=\"MsoNormal\"\u003eThe Triggerscope 4 is a customizable, high speed DAC and TTL I\/O device designed for control over common laboratory and industrial equipment. The Triggerscope can be controlled via serial connection and has open-source human-readable commands for all communication. Drivers are available for Starlyte Nebula, Micromanager (built in), Metamorph, ImagePro, Volocity, MATLAB, and other programs. Documentation is available for custom driver and software support.  External power adapter included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLaser, LED, and AOTF control\u003c\/li\u003e\n\u003cli\u003eHigh speed camera triggering\u003c\/li\u003e\n\u003cli\u003ePiezo and fast focus control\u003c\/li\u003e\n\u003cli\u003eHigh speed synchronization\u003c\/li\u003e\n\u003cli\u003eStrobe capture\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 100.357%; height: 94.3751px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1875px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 55.1875px;\"\u003eMicrocontroller\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; height: 55.1875px; text-align: left;\"\u003e600 Mhz, 1024KB RAM\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; height: 55.1875px; text-align: left;\"\u003e16GB external memory card included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eDAC Channels\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eSMA (F) connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eDAC Output\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e0-5V, ±5V, 0-10V, ±10V, ±2.5V\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e±40mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eDAC Output\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e270kHz max\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eTTL Channels\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e16\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eSMA (F) connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eTTL Output\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e0-5V\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e500ma (1-4), 200ma (5-16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eTTL Output\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e\u0026lt;10us rise\/fall\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003eTrigger Inputs\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left;\"\u003e5V or 3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Advanced Research Consulting","offers":[{"title":"Default Title","offer_id":53104972366121,"sku":"TG4B","price":3500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/tg41.png?v=1778005607"},{"product_id":"triggerscope-mini-usb-powered-ttl-dac-controller","title":"Triggerscope Mini - USB Powered TTL\/DAC Controller","description":"\u003cp class=\"p1\"\u003eProfessional-grade synchronization in a compact, USB-powered package.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eThe TriggerScope Mini brings hardware-timed DAC and TTL control to any microscope at an accessible price.  It features native MicroManager compatibility, 2 analog outputs, 4 digital outputs, and a trigger input.  USB-C cable included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTypical applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh speed synchronization\u003c\/li\u003e\n\u003cli\u003eLaser, LED, and AOTF control\u003c\/li\u003e\n\u003cli\u003eHigh speed camera triggering\u003c\/li\u003e\n\u003cli\u003ePiezo and fast focus control\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100.357%; height: 157.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: center; height: 19.5938px;\"\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eDAC Channels\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eSMA (F) connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 20.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 20.5938px;\"\u003eDAC Output\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 20.5938px;\"\u003e0-5V\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 20.5938px;\"\u003e12-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eTTL Channels\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eSMA (F) connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eTTL Output\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003e0-5V\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eUp to 250 sequenced states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eTrigger Inputs\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"width: 33.0325%; text-align: left; height: 19.5938px;\"\u003eSMA (F) connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Advanced Research Consulting","offers":[{"title":"Default Title","offer_id":53105538629929,"sku":"TG-MINI","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/Triggerscope_Mini-scaled-e1772071880568.png?v=1778011903"},{"product_id":"starlyte-nebula-microscope-control-software","title":"Starlyte Nebula - Microscope Control Software","description":"\u003cp\u003e\u003cspan data-sfc-root=\"c\" data-wiz-uids=\"ktxHWe_g\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cspan data-subtree=\"aimfl,mfl\" data-processed=\"true\"\u003e\u003cspan class=\"N9Q8Lc\"\u003eStarlyte Nebula is an innovative, third-party microscopy image acquisition and control software developed for scientific research and industrial inspection. It features an intuitive user interface designed to manage complex hardware while supporting both simple and advanced automated systems.  \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-sfc-root=\"c\" data-wiz-uids=\"ktxHWe_g\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cspan data-subtree=\"aimfl,mfl\" data-processed=\"true\"\u003e\u003cspan class=\"N9Q8Lc\"\u003eNebula supports countless devices from dozens of manufacturers, including microscopes, cameras, LEDs, stages, lasers, and spinning disk confocal imagers.  Just ask about any hardware you need to control.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-sfc-root=\"c\" data-wiz-uids=\"ktxHWe_g\" data-sfc-cb=\"\" data-processed=\"true\"\u003e\u003cspan data-subtree=\"aimfl,mfl\" data-processed=\"true\"\u003e\u003cspan class=\"N9Q8Lc\"\u003eLive demonstrations available.\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePrice includes a perpetual license with one year of software support and updates.  Ongoing support and additional modules including slide scanning, deconvolution, and metrology are available.  Please contact us for additional information or a customized quote.\u003c\/p\u003e","brand":"Advanced Research Consulting","offers":[{"title":"Default Title","offer_id":53120185696553,"sku":"SLN","price":4600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/Screenshot-2026-04-20-122503-scaled.png?v=1778090887"},{"product_id":"ms-2000-ft-xy-automated-microscope-stage-and-controller","title":"MS-2000 FT - XY Automated Microscope Stage and Controller","description":"\u003cp\u003eThe MS-2000 FT (Flat-Top) Stage is a high-precision automated microscope stage made by Applied Scientific Instrumentation (ASI). It is designed to provide a high-resolution and highly repeatable means of controlling the X\/Y position of a microscope stage, and is compatible with a wide range of microscope brands and models, including Leica, Nikon, Evident\/Olympus and Zeiss.  The MS-2000 controller provides joystick control and facilitates communication via USB or RS-232 serial, and supports TTL synchronization.  ASI products are supported by software from most scope manufacturers, as well as Micro-Manager, Nebula, VisiView, Inscoper, Slidebook, MetaMorph, and more (SDK available).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe MS-2000 is ideal for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated Multipoint and Tile Imaging\u003c\/li\u003e\n\u003cli\u003eLive Cell Imaging, Organism Tracking, and Time-Lapse Microscopy\u003c\/li\u003e\n\u003cli\u003eRaster and Serpentine Scanning\u003c\/li\u003e\n\u003cli\u003eMicromanipulation and Microinjection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 137.157px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd class=\"table-title\" colspan=\"2\" style=\"width: 99.639%; text-align: center; height: 19.5938px;\"\u003e\n\u003cstrong\u003eMS-2000 Stage Specifications\u003c\/strong\u003e (standard configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"col-headers\" style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 67.87%; height: 19.5938px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 31.769%; height: 19.5938px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis range of travel\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e120 mm × 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis resolution (encoder step)\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e22 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis RMS repeatability\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e\u0026lt; 700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis maximum velocity\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e7 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eMax recommended load (6.35mm screw pitch)\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMany options are available, including piezo plates for Z motion, linear encoders for increased accuracy, stage wings for mounting, and alternative lead screw pitches.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis just a partial list of the microscope models that can be compatible with the MS-2000 stage:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvident\/Olympus\u003c\/strong\u003e: IX85, IX73\/83, IX71\/81, IX70, BX53\/63, BX51\/61, BX50, BH2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLeica\u003c\/strong\u003e: DMi8, DMI6000, DMI5000, DMI4000, DM IL, DMIRBE, DMIRB, DMIRE\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNikon\u003c\/strong\u003e: Eclipse Ti2, Ti-E, Ti-U, Ti-S, TE2000, TE200, TE300, Diaphot, Optiphot\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZeiss\u003c\/strong\u003e: Axiovert, Axio Examiner, Axio Observer, Axio Imager, Axiovert 200, AxioPhot, AxioPlan, AxioLab\u003c\/p\u003e\n\u003cp\u003eIf you have a scope not listed here, please inquire about compatibility.\u003c\/p\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-baqh{text-align:center;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e","brand":"ASI","offers":[{"title":"Default Title","offer_id":53197955760425,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/ms2000ft-photo-01.jpg?v=1779376932"},{"product_id":"pz-2000-ft-xyz-automated-microscope-stage-with-piezo-z","title":"PZ-2000 FT - XYZ Automated Microscope Stage with Piezo Z-Axis and Controller","description":"\u003cp\u003eThe PZ-2000 FT (Flat-Top) Stage is a high-precision automated microscope stage made by Applied Scientific Instrumentation (ASI). It is designed to provide a high-resolution and highly repeatable means of controlling the X\/Y\/Z position of a microscope stage, and is compatible with a wide range of microscope brands and models, including Leica, Nikon, Evident\/Olympus and Zeiss.  The MS-2000 controller provides joystick control and facilitates communication via USB or RS-232 serial, and supports TTL synchronization.  ASI products are supported by software from most scope manufacturers, as well as Micro-Manager, Nebula, VisiView, Inscoper, Slidebook, MetaMorph, and more (SDK available).\u003c\/p\u003e\n\u003cp\u003eIn addition to X\/Y motorization, the PZ-2000 also features a piezo Z-axis positioner.  Piezo systems offer better accuracy, faster movement, and improved stability compared to traditional Z microscope drives. The fast response of piezo Z enables rapid Z-stacks for 3D volumetric imaging and improved data for any imaging where quantification is critical.\u003c\/p\u003e\n\u003cp\u003eThe PZ-2000 is ideal for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3D imaging\u003c\/li\u003e\n\u003cli\u003eDeconvolution\u003c\/li\u003e\n\u003cli\u003eLive Cell Imaging, Organism Tracking, and Time-Lapse Microscopy\u003c\/li\u003e\n\u003cli\u003eSuper resolution imaging\u003c\/li\u003e\n\u003cli\u003eTIRF imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 137.157px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 99.639%; text-align: center; height: 19.5938px;\" colspan=\"2\" class=\"table-title\"\u003e\n\u003cstrong\u003ePZ-2000 Stage Specifications\u003c\/strong\u003e (standard configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\" class=\"col-headers\"\u003e\n\u003cth style=\"width: 67.87%; height: 19.5938px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 31.769%; height: 19.5938px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis range of travel\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e120 mm × 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis resolution (encoder step)\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e22 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis RMS repeatability\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e\u0026lt; 700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eX- and Y-axis maximum velocity\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e7 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 67.87%; height: 19.5938px;\"\u003eMax recommended load (6.35mm screw pitch)\u003c\/td\u003e\n\u003ctd style=\"width: 31.769%; height: 19.5938px;\"\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"container\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" class=\"table-title\"\u003eADEPT Piezo Controller Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"col-headers\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003ePZ-2150\u003c\/th\u003e\n\u003cth\u003ePZ-2300\u003c\/th\u003e\n\u003cth\u003ePZ-2500\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiezo travel range (± 5%)\u003c\/td\u003e\n\u003ctd\u003e150 μm\u003c\/td\u003e\n\u003ctd\u003e300 μm\u003c\/td\u003e\n\u003ctd\u003e500 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiezo smallest move \/ resolution *\u003c\/td\u003e\n\u003ctd\u003e2.2 nm\u003c\/td\u003e\n\u003ctd\u003e4.5 nm\u003c\/td\u003e\n\u003ctd\u003e7.6 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load for full range travel\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"800\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient response time**\u003c\/td\u003e\n\u003ctd\u003e11–15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal analog input (BNC)\u003c\/td\u003e\n\u003ctd\u003e0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input frequency\u003c\/td\u003e\n\u003ctd\u003e20 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current\u003c\/td\u003e\n\u003ctd\u003e13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ci\u003e**Time taken to travel 10%-90% for moves below 30% travel range with 600 g load.\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003eMany options are available, including, linear encoders for increased accuracy, stage wings for mounting, and alternative lead screw pitches.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eThis just a partial list of the microscope models that can be compatible with the PZ-2000 stage:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEvident\/Olympus\u003c\/strong\u003e: IX85, IX73\/83, IX71\/81, IX70, BX53\/63, BX51\/61, BX50, BH2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLeica\u003c\/strong\u003e: DMi8, DMI6000, DMI5000, DMI4000, DM IL, DMIRBE, DMIRB, DMIRE\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNikon\u003c\/strong\u003e: Eclipse Ti2, Ti-E, Ti-U, Ti-S, TE2000, TE200, TE300, Diaphot, Optiphot\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eZeiss\u003c\/strong\u003e: Axiovert, Axio Examiner, Axio Observer, Axio Imager, Axiovert 200, AxioPhot, AxioPlan, AxioLab\u003c\/p\u003e\n\u003cp\u003eIf you have a scope not listed here, please inquire about compatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-baqh{text-align:center;vertical-align:top}\n.tg .tg-0lax{text-align:left;vertical-align:top}\n\u003c\/style\u003e","brand":"ASI","offers":[{"title":"Default Title","offer_id":53207655383337,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/pz-2000-ft-photo-01.jpg?v=1779805211"},{"product_id":"fw-1000-high-speed-filter-wheel","title":"FW-1000 High Speed Filter Wheel","description":"\u003cp\u003eThe FW-1000 is a high-speed filter wheel featuring extremely low vibration and ultra fast switching speed. Designed for research-grade microscopes but suitable for many more purposes, it is used to automatically swap optical filters (or any similar sized optics) during imaging. \u003c\/p\u003e\n\u003cp\u003eThe FW-1000 can be mounted on just about any microscope.  For fluorescence emission control it can be configured with C-mount, F-mount, camera port, or custom connectors as needed. For illumination control it can be outfitted with epi-illumination port adapters for Evident\/Olympus, Leica, Nikon, Zeiss, or many other microscopes.  \u003c\/p\u003e\n\u003cp\u003eA single FW controller can govern up to two filter wheels, and communicates via USB, RS-232 serial, or TTL triggers and preprogrammed sequences. \u003cspan\u003eASI products are supported by software from most microscope manufacturers, as well as Micro-Manager, Nebula, VisiView, Inscoper, Slidebook, MetaMorph, and more (SDK available).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe FW-1000 is ideal for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eHigh speed fluorescence imaging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLife science microscopy\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpectral selection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eIntensity control\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" width=\"800\" style=\"height: 121.219px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19.5938px; width: 281.641px;\"\u003eMinimum Switching Time\u003c\/td\u003e\n\u003ctd width=\"392\" style=\"height: 19.5938px; width: 256.359px;\"\u003e\u0026lt; 40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 23.25px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 23.25px; width: 281.641px;\"\u003eMaximum Vibration Torque Impulse\u003c\/td\u003e\n\u003ctd style=\"height: 23.25px; width: 256.359px;\"\u003e\u0026lt; 3 x 10\u003csup\u003e-4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ekg·m\u003csup\u003e2\u003c\/sup\u003e\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"2\" width=\"228\" style=\"height: 39.1876px; width: 165.297px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd width=\"158\" style=\"height: 19.5938px; width: 116.344px;\"\u003eFilter Wheel\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 256.359px;\"\u003e203 mm x 118 mm x 29 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 116.344px;\"\u003eController\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 256.359px;\"\u003e58 mm H x 142 mm W x 194 mm L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd rowspan=\"2\" style=\"height: 39.1876px; width: 165.297px;\"\u003eFilter specifications\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 116.344px;\"\u003eMax. Thickness\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 256.359px;\"\u003e5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 116.344px;\"\u003eMounting Angle\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 256.359px;\"\u003e\u003cspan\u003e4° (standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe FW-1000 is available in multiple configurations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8-Position Filter Wheel Disk for 25 mm diameter filters\u003c\/li\u003e\n\u003cli\u003e6-Position Filter Wheel Disk for 32 mm diameter filters\u003c\/li\u003e\n\u003cli\u003e16-Position Filter Wheel Disk for 25 mm diameter filters\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ASI","offers":[{"title":"Default Title","offer_id":53208099815721,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/FW-1000-SA_A.jpg?v=1779820265"},{"product_id":"optosplit-ii-image-splitter-from-cairn-research","title":"OptoSplit II - Image Splitter from Cairn Research","description":"\u003cp\u003e\u003cspan\u003eThe Cairn Research OptoSplit II emission image splitter is a simple device that allows a single camera to record images simultaneously at two different optical wavelengths, polarization states, or other differentiated states.  It\u003c\/span\u003e\u003cspan\u003e divides an image into two separate, spatially identical components, displayed side by side on a single sensor - effectively doubling research capacity with just one camera. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditionally, dual channel imaging is performed using an electronic filter changer. The switching speed of an electronic filter changer is a major limitation to speed and science.  With the OptoSplit, two images are captured in parallel with no time lost to switching filters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe OptoSplit uses a unique rotating mirror cradle to ensure excellent image registration and features a fully adjustable rectangular aperture to enable cropped sensor imaging modes and reduce scatter.  Cairn's proprietary lens design supports sensors up to 29.4mm diagonal.  The large aperture design results in improved off-axis correction that maximizes image flatness and minimizes chromatic distortion to give enhanced performance with all sensors.  All optical surfaces feature AR coatings, 425nm to 875nm.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe OptoSplit II is ideal for many scientific applications, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous multi-fluorescent probe imaging\u003c\/li\u003e\n\u003cli\u003eLive cell and high speed imaging\u003c\/li\u003e\n\u003cli\u003eFörster Resonance Energy Transfer (FRET)\u003c\/li\u003e\n\u003cli\u003eRatiometric calcium, voltage \u0026amp; pH imaging\u003c\/li\u003e\n\u003cli\u003ePolarization studies (anisotropy)\u003c\/li\u003e\n\u003cli\u003eSimultaneous fluorescence and transmitted\/DIC\/phase imaging\u003c\/li\u003e\n\u003cli\u003eSimultaneous dual Z depth imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe OptoSplit II is simple to add to most microscopes, and is compatible with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinning disk confocal microscopy\u003c\/li\u003e\n\u003cli\u003eTotal Internal Reflection Fluorescence (TIRF)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLight sheet and Single Plane Illumination Microscopy (SPIM)\u003c\/li\u003e\n\u003cli\u003e3D super resolution PALM\/STORM (using cylindrical lenses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eImaging with the OptoSplit does not require any custom camera drivers.  However, many software packages include useful tools to assist with registration and analysis.  An OptoSplit plugin is also available in ImageJ (Fiji) and MicroManager.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis OptoSplit II package includes the following:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC-mount input and output connections (22mm FOV)\u003c\/li\u003e\n\u003cli\u003e1x magnification optics\u003c\/li\u003e\n\u003cli\u003eRectangular input diaphragm\u003c\/li\u003e\n\u003cli\u003e1 Empty filter cube (requires 25mm emission filters, 26x38x2mm dichroic)\u003c\/li\u003e\n\u003cli\u003eCalibration cube\u003c\/li\u003e\n\u003cli\u003e1 OptoSplit support jack\u003c\/li\u003e\n\u003cli\u003eShutter plate\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFilters not included.  Alternate adapters are available for larger field-of-view, such as F-Mount or T-Mount.  1.3x and 1.7x magnification optics are available upon request.  Contact us for polarization options including a beamsplitter cube and rotatable polarizer, or multifocal optics.  Additional filter cubes and drop-in 25mm holders are available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe are happy to recommend and supply filter sets.  Please contact us to discuss your application.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cairn Research","offers":[{"title":"Default Title","offer_id":53212094300457,"sku":"P280\/210\/000-BUNDLE","price":13980.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/OptoSplit-II-Product-1.jpg?v=1779907507"},{"product_id":"twincam-dual-emission-image-splitter-from-cairn-research","title":"TwinCam - Dual Emission Image Splitter from Cairn Research","description":"\u003cp\u003e\u003cspan\u003eThe Cairn Research TwinCam is a dual-camera emission image splitter designed for high-performance fluorescence microscopy and similar multi-modal imaging. It separates emission light by wavelength, polarization state, focal position, or imaging modality so that it can be imaged simultaneously by two separate cameras.  This allows for scientific imaging to happen with no temporal artifacts, and no loss of field-of-view.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditionally, dual channel imaging is performed using an electronic filter changer. The switching speed of an electronic filter changer is a major limitation to speed and science.  With the TwinCam, two images are captured in parallel with no time lost to switching filters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe TwinCam uses custom optics and highly stable mounting to ensure excellent image registration and features a fully adjustable rectangular aperture to enable cropped sensor imaging modes and reduce scatter.  Cairn's proprietary lens design supports sensors up to 31.9mm diagonal.  The large aperture design results in improved off-axis correction that maximizes image flatness and minimizes chromatic distortion to give enhanced performance with all sensors.  All optical surfaces feature AR coatings, 425nm to 875nm.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe TwinCam is ideal for many scientific applications, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous multi-fluorescent probe imaging\u003c\/li\u003e\n\u003cli\u003eLive cell and high speed imaging\u003c\/li\u003e\n\u003cli\u003eFörster Resonance Energy Transfer (FRET)\u003c\/li\u003e\n\u003cli\u003eRatiometric calcium, voltage \u0026amp; pH imaging\u003c\/li\u003e\n\u003cli\u003ePolarization studies (anisotropy)\u003c\/li\u003e\n\u003cli\u003eSimultaneous fluorescence and transmitted\/DIC\/phase imaging\u003c\/li\u003e\n\u003cli\u003eSimultaneous dual Z depth imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe TwinCam is simple to add to most microscopes, and is compatible with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinning disk confocal microscopy\u003c\/li\u003e\n\u003cli\u003eTotal Internal Reflection Fluorescence (TIRF)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLight sheet and Single Plane Illumination Microscopy (SPIM)\u003c\/li\u003e\n\u003cli\u003e3D super resolution PALM\/STORM (using cylindrical lenses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe TwinCam can be used with any software package that supports simultaneous capture from two cameras.  This includes most microscope software, as well as \u003cspan\u003eMicro-Manager, Nebula, VisiView, Inscoper, Slidebook, MetaMorph, and more.  Specific software modules may be required\u003c\/span\u003e.  \u003cspan\u003eCamera TTL synchronization may be necessary for optimal results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis TwinCam package includes the following:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC-mount input and output connections (22mm FOV)\u003c\/li\u003e\n\u003cli\u003e1x magnification optics\u003c\/li\u003e\n\u003cli\u003eRectangular input diaphragm\u003c\/li\u003e\n\u003cli\u003e1 Empty filter cube (requires 25mm emission filters, 26x38x2mm dichroic)\u003c\/li\u003e\n\u003cli\u003e1 Calibration cube\u003c\/li\u003e\n\u003cli\u003e2 Angled auxiliary filter holders\u003c\/li\u003e\n\u003cli\u003e2 Support jacks\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFilters not included.  Alternate adapters are available for larger field-of-view, such as F-Mount or T-Mount.  1.3x and 1.7x magnification optics are available upon request.  Contact us for polarization options including a beamsplitter cube and rotatable polarizer, or multifocal optics.  Additional filter cubes and drop-in 25mm holders are available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe are happy to recommend and supply filter sets.  Please contact us to discuss your application.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cairn Research","offers":[{"title":"Default Title","offer_id":53212130869545,"sku":"P1075\/010\/000-BUNDLE","price":11375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/TwinCam-Product-Square.png?v=1779911039"},{"product_id":"optosplit-ii-bp-image-splitter-with-bypass","title":"OptoSplit II BP - Image Splitter with Bypass","description":"\u003cp\u003e\u003cspan\u003eThe Cairn Research OptoSplit II BP emission image splitter is a device that allows a single camera to record images simultaneously at two different optical wavelengths, polarization states, or other differentiated states.  It\u003c\/span\u003e\u003cspan\u003e divides an image into two separate, spatially identical components, displayed side by side on a single sensor - effectively doubling research capacity with just one camera. The BP version adds a convenient single lever \"bypass\" mode ideal for multi-user microscopes, or any setup where simultaneous dual channels are not required for all \u003cimg\u003eimaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditionally, dual channel imaging is performed using an electronic filter changer. The switching speed of an electronic filter changer is a major limitation to speed and science.  With the OptoSplit, two images are captured in parallel with no time lost to switching filters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe OptoSplit uses a unique rotating mirror cradle to ensure excellent image registration and features a fully adjustable rectangular aperture to enable cropped sensor imaging modes and reduce scatter.  Cairn's proprietary lens design supports sensors up to 29.4mm diagonal.  The large aperture design results in improved off-axis correction that maximizes image flatness and minimizes chromatic distortion to give enhanced performance with all sensors.  All optical surfaces feature AR coatings, 425nm to 875nm.  The BP version has a slightly larger footprint with additional space for more auxiliary components.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe OptoSplit II BP is ideal for many scientific applications, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous multi-fluorescent probe imaging\u003c\/li\u003e\n\u003cli\u003eLive cell and high speed imaging\u003c\/li\u003e\n\u003cli\u003eFörster Resonance Energy Transfer (FRET)\u003c\/li\u003e\n\u003cli\u003eRatiometric calcium, voltage \u0026amp; pH imaging\u003c\/li\u003e\n\u003cli\u003ePolarization studies (anisotropy)\u003c\/li\u003e\n\u003cli\u003eSimultaneous fluorescence and transmitted\/DIC\/phase imaging\u003c\/li\u003e\n\u003cli\u003eSimultaneous dual Z depth imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe OptoSplit II BP is simple to add to most microscopes, and is compatible with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinning disk confocal microscopy\u003c\/li\u003e\n\u003cli\u003eTotal Internal Reflection Fluorescence (TIRF)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLight sheet and Single Plane Illumination Microscopy (SPIM)\u003c\/li\u003e\n\u003cli\u003e3D super resolution PALM\/STORM (using cylindrical lenses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eImaging with the OptoSplit does not require any custom camera drivers.  However, many software packages include useful tools to assist with registration and analysis.  An OptoSplit plugin is also available in ImageJ (Fiji) and MicroManager.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis OptoSplit II BP package includes the following:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC-mount input and output connections (22mm FOV)\u003c\/li\u003e\n\u003cli\u003e1x magnification optics\u003c\/li\u003e\n\u003cli\u003eRectangular input diaphragm\u003c\/li\u003e\n\u003cli\u003e1 Empty filter cube (requires 25mm emission filters, 26x38x2mm dichroic)\u003c\/li\u003e\n\u003cli\u003eCalibration cube\u003c\/li\u003e\n\u003cli\u003e1 OptoSplit support jack\u003c\/li\u003e\n\u003cli\u003eShutter plate\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSingle lever switching between split mode and bypass mode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFilters not included.  Alternate adapters are available for larger field-of-view, such as F-Mount or T-Mount.  1.3x \u003cspan style=\"font-size: 0.875rem;\"\u003emagnification optics are available upon request.  Contact us for polarization options including a beamsplitter cube and rotatable polarizer, or multifocal optics.  Additional filter cubes and drop-in 25mm holders are available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe are happy to recommend and supply filter sets.  Please contact us to discuss your application.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cairn Research","offers":[{"title":"Default Title","offer_id":53212211118377,"sku":"P280\/210\/000-0BP-BUNDLE","price":19560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/OptoSplit-II-ByPass-Product-1.jpg?v=1779913658"},{"product_id":"optosplit-iii-triple-image-splitter-from-cairn-research","title":"OptoSplit III - Triple Image Splitter from Cairn Research","description":"\u003cp\u003e\u003cspan\u003eThe Cairn Research OptoSplit III \"TripleSplit\" emission image splitter is a device that allows a single camera to record images simultaneously at two or three different optical wavelengths, polarization states, or other differentiated states.  It\u003c\/span\u003e\u003cspan\u003e divides an image into separate, spatially identical components, displayed side by side on a single sensor - effectively increasing research capacity with just one camera. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditionally, multi-channel imaging is performed using an electronic filter changer.  The switching speed of an electronic filter changer is a major limitation to speed and science.  The OptoSplit III can be configured to capture either two or three images in parallel, with no time lost to switching filters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe OptoSplit uses a unique rotating mirror cradle to ensure excellent image registration and features a fully adjustable rectangular aperture to enable cropped sensor imaging modes and reduce scatter.  Cairn's proprietary lens design supports sensors up to 29.4mm diagonal (25mm using single channel cube).  The large aperture design results in improved off-axis correction that maximizes image flatness and minimizes chromatic distortion to give enhanced performance with all sensors.  All optical surfaces feature AR coatings, 425nm to 875nm.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe OptoSplit III is ideal for many scientific applications, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous multi-fluorescent probe imaging\u003c\/li\u003e\n\u003cli\u003eLive cell and high speed imaging\u003c\/li\u003e\n\u003cli\u003eFörster Resonance Energy Transfer (FRET)\u003c\/li\u003e\n\u003cli\u003eRatiometric calcium, voltage \u0026amp; pH imaging\u003c\/li\u003e\n\u003cli\u003ePolarization studies (anisotropy)\u003c\/li\u003e\n\u003cli\u003eSimultaneous fluorescence and transmitted\/DIC\/phase imaging\u003c\/li\u003e\n\u003cli\u003eSimultaneous multi Z depth imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe OptoSplit III is simple to add to most microscopes, and is compatible with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinning disk confocal microscopy\u003c\/li\u003e\n\u003cli\u003eTotal Internal Reflection Fluorescence (TIRF)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLight sheet and Single Plane Illumination Microscopy (SPIM)\u003c\/li\u003e\n\u003cli\u003e3D super resolution PALM\/STORM (using cylindrical lenses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eImaging with the OptoSplit does not require any custom camera drivers.  However, many software packages include useful tools to assist with registration and analysis.  An OptoSplit plugin is also available in ImageJ (Fiji) and MicroManager.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis OptoSplit III package includes the following:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC-mount input and output connections (22mm FOV)\u003c\/li\u003e\n\u003cli\u003e1x magnification optics\u003c\/li\u003e\n\u003cli\u003eRectangular input diaphragm\u003c\/li\u003e\n\u003cli\u003e1 Empty triple filter cube (requires 3x 25mm emission filters, 2x 26x38x2mm dichroic)\u003c\/li\u003e\n\u003cli\u003e1 Empty filter cube for two channel imaging (requires 2x 25mm emission filters, 1x 26x38x2mm dichroic)\u003c\/li\u003e\n\u003cli\u003eCalibration cube\u003c\/li\u003e\n\u003cli\u003e1 OptoSplit support jack\u003c\/li\u003e\n\u003cli\u003e2 Shutter plates\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFilters not included.  Alternate adapters are available for larger field-of-view, such as F-Mount or T-Mount.  1.3x magnification optics are available upon request.  Contact us for polarization options including a beamsplitter cube and rotatable polarizer, or multifocal optics.  Additional filter cubes and drop-in 25mm holders are available. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe are happy to recommend and supply filter sets.  Please contact us to discuss your application.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cairn Research","offers":[{"title":"Default Title","offer_id":53212269412649,"sku":"P280\/310\/000-BUNDLE","price":21510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/OptoSplit-III-Product-1.jpg?v=1779916468"},{"product_id":"multisplit-products-from-cairn-research","title":"MultiSplit products from Cairn Research","description":"\u003cp\u003e\u003cspan\u003eThe MultiSplit family of products from Cairn Research are emission image splitters that allow a single camera to record multiple images simultaneously.  Images can be split based on different optical wavelengths, polarization states, focal plane, or other differentiated states.  They\u003c\/span\u003e\u003cspan\u003e divide an image into separate, spatially identical components, displayed on a single sensor.  MultiSplit products are a highly effective way to  greatly increasing research capacity with just one camera. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditionally, multi-channel imaging is performed using an electronic filter changer.  The switching speed of an electronic filter changer is a major limitation to speed and science.  MultiSplit products can be configured to capture two, three, or even four images in parallel, with no time lost to switching filters.  They were first designed for quantitative fluorescence microscopy, but are suitable for use with any imaging where simultaneous and synchronous image capture is needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMultiSplit products use a unique rotating mirror cradle to ensure excellent image registration. Cairn's proprietary lens design supports very large sensors; cameras with 22mm, 25mm, 29.4mm, and even 31.9mm FOV can be used to their fullest extent.  The large aperture design results in improved off-axis correction that maximizes image flatness and minimizes chromatic distortion to give enhanced performance with all sensors.  All optical surfaces feature AR coatings, 425nm to 875nm.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMultiSplit products are ideal for many scientific applications, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous multi-fluorescent probe imaging\u003c\/li\u003e\n\u003cli\u003eLive cell and high speed imaging\u003c\/li\u003e\n\u003cli\u003eFörster Resonance Energy Transfer (FRET)\u003c\/li\u003e\n\u003cli\u003eRatiometric calcium, voltage \u0026amp; pH imaging\u003c\/li\u003e\n\u003cli\u003ePolarization studies (anisotropy)\u003c\/li\u003e\n\u003cli\u003eSimultaneous fluorescence and transmitted\/DIC\/phase imaging\u003c\/li\u003e\n\u003cli\u003eSimultaneous multi Z depth imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMultiSplit products are simple to add to most microscopes, and are compatible with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinning disk confocal microscopy\u003c\/li\u003e\n\u003cli\u003eTotal Internal Reflection Fluorescence (TIRF)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLight sheet and Single Plane Illumination Microscopy (SPIM)\u003c\/li\u003e\n\u003cli\u003e3D super resolution PALM\/STORM (using cylindrical lenses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eImaging with a MultiSplit does not require any custom camera drivers.  However, many software packages include useful tools to assist with registration and analysis.  A MultiSplit plugin is also available in ImageJ (Fiji) and MicroManager.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMultiSplit products can be manufactured with many options, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC-mount, F-mount, T-mount, or direct microscope couplings\u003c\/li\u003e\n\u003cli\u003eSupport for up to 31.9mm FOV cameras, depending on options\u003c\/li\u003e\n\u003cli\u003eBuilt in magnification options: 1x, 1.3x, or 1.7x\u003c\/li\u003e\n\u003cli\u003eIntegrated filter wheels\u003c\/li\u003e\n\u003cli\u003eBypass options\u003c\/li\u003e\n\u003cli\u003eAuxiliary paddles for fast filter switching\u003c\/li\u003e\n\u003cli\u003eRectangular diaphragms\u003c\/li\u003e\n\u003cli\u003ePolarization optics\u003c\/li\u003e\n\u003cli\u003eMultifocal optics\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport jacks\u003c\/li\u003e\n\u003cli\u003eShutter plates\u003c\/li\u003e\n\u003cli\u003eCustom mechanical modifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe are happy to help you design the perfect MultiSplit product to fit your microscopy.  Please contact us to discuss your application.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cairn Research","offers":[{"title":"Default Title","offer_id":53213710876969,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/MultiSplit-V2-Product-1.jpg?v=1779981563"},{"product_id":"multicam-products-from-cairn-research","title":"MultiCam products from Cairn Research","description":"\u003cp\u003e\u003cspan\u003eThe MultiCam family of products from Cairn Research are emission image splitters that allow multiple cameras to record images simultaneously.  Images can be split based on different optical wavelengths, polarization states, focal planes, or other differentiated states.  They\u003c\/span\u003e\u003cspan\u003e divide an image into separate, spatially identical components.  This allows for scientific imaging to happen with no temporal artifacts, and at full field-of-view.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTraditionally, multi-channel imaging is performed using an electronic filter changer.  The switching speed of an electronic filter changer is a major limitation to speed and science.  MultiCam products can be configured to capture two, three, four, or more images in parallel, with no time lost to switching filters.  They were first designed for quantitative fluorescence microscopy, but are suitable for use with any imaging where simultaneous and synchronous image capture is needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMultiCam products use \u003cspan\u003ecustom optics and highly stable mounting\u003c\/span\u003e to ensure excellent image registration. Cairn's proprietary lens design supports very large sensors; cameras with 22mm, 25mm, 29.4mm, and even 31.9mm FOV can be used to their fullest extent.  The large aperture design results in improved off-axis correction that maximizes image flatness and minimizes chromatic distortion to give enhanced performance with all sensors.  All optical surfaces feature AR coatings, 425nm to 875nm.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMultiCam products are ideal for many scientific applications, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous multi-fluorescent probe imaging\u003c\/li\u003e\n\u003cli\u003eLive cell and high speed imaging\u003c\/li\u003e\n\u003cli\u003eFörster Resonance Energy Transfer (FRET)\u003c\/li\u003e\n\u003cli\u003eRatiometric calcium, voltage \u0026amp; pH imaging\u003c\/li\u003e\n\u003cli\u003ePolarization studies (anisotropy)\u003c\/li\u003e\n\u003cli\u003eSimultaneous fluorescence and transmitted\/DIC\/phase imaging\u003c\/li\u003e\n\u003cli\u003eSimultaneous multi Z depth imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMultiSplit products are simple to add to most microscopes, and are compatible with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpinning disk confocal microscopy\u003c\/li\u003e\n\u003cli\u003eTotal Internal Reflection Fluorescence (TIRF)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLight sheet and Single Plane Illumination Microscopy (SPIM)\u003c\/li\u003e\n\u003cli\u003e3D super resolution PALM\/STORM (using cylindrical lenses)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMultiCam products can be used with any software package that supports simultaneous capture from multiple cameras.  This includes most microscope software, as well as \u003c\/span\u003e\u003cspan\u003eMicro-Manager, Nebula, VisiView, Inscoper, Slidebook, MetaMorph, and more.  Specific software modules may be required\u003c\/span\u003e\u003cspan\u003e.  Camera TTL synchronization may be necessary for optimal results.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMutliCam products can be manufactured with many options, including:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eC-mount, F-mount, T-mount, or direct microscope couplings\u003c\/li\u003e\n\u003cli\u003eSupport for up to 31.9mm FOV cameras, depending on options\u003c\/li\u003e\n\u003cli\u003eBuilt in magnification options: 1x, 1.3x, or 1.7x\u003c\/li\u003e\n\u003cli\u003eIntegrated filter wheels\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAuxiliary paddles for fast filter switching\u003c\/li\u003e\n\u003cli\u003eRectangular diaphragms\u003c\/li\u003e\n\u003cli\u003ePolarization optics\u003c\/li\u003e\n\u003cli\u003eMultifocal optics\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport jacks\u003c\/li\u003e\n\u003cli\u003eShutter plates\u003c\/li\u003e\n\u003cli\u003eCustom mechanical modifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eWe are happy to help you design the perfect MultiSplit product to fit your microscopy.  Please contact us to discuss your application.\u003c\/em\u003e\u003c\/p\u003e","brand":"Cairn Research","offers":[{"title":"Default Title","offer_id":53214044881193,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0452\/4209\/files\/MultiCam-1.jpg?v=1779991592"}],"url":"https:\/\/microscopecentral.com\/collections\/research.oembed","provider":"Microscope Central","version":"1.0","type":"link"}